Kenmore 795.775636 Refrigerator User Manual


 
- 20 -
Housing-A
Main PCB
BO
BO
BO
BO
D-Sensor
7
8
2
1
CON6
7
6
Defrost Sensor Error
Wiring dia gram
Is Er-dS displayed?
Disconnect CON6 and measure
the value. Is resistance value
between pins 7 & 8 of CON6 as
below? (BO to BO)
Yes
Is the connection loose?
If the ER-dS appears, Replace
the main PCB. Otherwise,
explain to the customer!
Replace
D-sensor
No
No
No
pin8
pin7
6 ~ 300k‰Pin7 to pin8
ResultTest Point
Reconnect
Reconnect and Power ON
Power Off
Tip : To protection of MICOM
Is resistance value between
pins 1 & 2 of Housing- A as
below? (BO to BO)
Replace a
D-Sensor
pin1
pin2
1.156 ~141.5k‰Pin1 To pin2
ResultTest Point
Checking Open or Short of wire
Yes
Yes
No