Kenmore Elite Refrigerator User Manual


 
PRODUCT DATA SHEET
Base Grille Water Filtration System
Model TIKB1/TIRFKB1 Capacity 100 Gallons (379 Liters)
(_ I Tested and certified by NSF International against NSF/ANSI Standard 42 for the reduction of
Chlorine Taste and Odor, Particulate Class I*; and against NSF/ANSl Standard 53 for the reduction of
Lead, Mercury, Atrazine, Benzene, Toxaphene, O-Dichlorobenzene, Cysts, Turbidity, Asbestos,
L ndane, Tetrach oroethy ene, Endr n, A ach or, Ch orobenzene, Ethy benzene, TTHM and MTBE.
This system has been tested according to NSF/ANSl 42/53 for the reduction of the substances listed below. The concentration of the
indicated substances in water entering the system was reduced to a concentration less than or equal to the permissible limit for water
leaving the system, as specified in NSF/ANSl 42/53.
Substance Reduction NSF Reduction Average Influent Challenge Maximum Average Minimum % Average %
Aesthetic Effects Requirements Influent Concentration Effluent Effluent Reduction Reduction
Chlorine Taste/Odor 50% reduction 2.0 mg/L 2.0 mg/L _+10% 0.08 mg/L 2.0 mg/L 95.93 97.36
Particulate Class I* 85% reduction 3533333#/mL At east 10,000 part c es/mL 22000 #/mL** 11567 #/mL 99.38 99.67
Contaminant NSF Reduction Average Influent Challenge Maximum Average Minimum % Average %
Reduction Requirements Influent Concentration Effluent Effluent Reduction Reduction
Lead: @ pH 6.5 0.010 mg/L 150 ug/L 0.15 mg/L _+10% 1.0 ug/L 1 ug/L 99.33 99.33
Lead: @ pH 8.5 0.010 mg/L 157 ug/L 0.15 mg/L _+10% 2.0 ug/L 1.08 ug/L 98.72 99.31
Mercury: @pH 6.5 0.002 mg/L 0.0058 mg/L 0.006 mg/L _+10% 0.0002 mg/L 0.0002 mg/L 96.53 96.53
Mercury: @pH 8.5 0.002 mg/L 0.0057 mg/L 0.006 mg/L _+10% 0.0002 mg/L 0.0002 mg/L 96.5 96.5
Benzene 0.005 mg/L 15 ug/L 0.015 mg/L _+10% 0.5 ug/L 0.5 ug/L 96.67 96.67
O-Dichlorobenzene 0.6 mg/L 1750 ug/L 1.8 _+10% 1.0 ug/L 1.0 ug/L 99.94 99.94
Toxaphene 0.003 mg/L 15 ug/L 0.015 _+10% 1.0 ug/L 1.0 ug/L 93.33 93.33
Atrazine 0.003 mg/L 10 ug/L 0.009 mg/L _+10% 2 ug/L 2 ug/L 80.8 80.8
Asbestos 99% 101 MFL 107to 108fibers/L *t 0.17 MFL 0.17 MFL 99.83 99.83
Live Cysts* >99.95% 120,000/L 50,000/L min. 8/12 l/L* 99.99 >99.99
Turbidity 0.5 NTU 11.4 NTU 11 _+1 NTU 0.41 NTU 0.24 NTU 96.4 97.89
Alachlor 0.002 mg/L 41.3 ug/L 0.04 _+10% 0.2 ug/L 0.2 ug/L 99.52 99.52
Endrin 0.002 mg/L 5.9 ug/L 0.006 _+10% 0.5 ug/L 0.3 ug/L 91.5 95.47
Ethylbenzene 0.7 mg/L 1867 ug/L 2.1 _+10% 0.70 ug/L 0.0588 ug/L 99.96 100
Lindane 0.002 mg/L 1.9 ug/L 0.002 _+10% 0.02 ug/L 0.02 ug/L 98.93 98.93
Chlorobenzene 0.6 mg/L 2.0 ug/L 2.0 _+10% 0.0005 ug/L 0.0005 ug/L 99.98 99.98
Tetrachloroethylene 0.005 mg/L 14.2 ug/L 0.015 _+10% 0.5 ug/L 0.5 ug/L 96.47 96.47
TTHM 0.080 mg/L 465 ug/L 0.45 _+20% 1.0 ug/L 0.5 ug/L 99.78 99.88
MTBE 0.005 mg/L 14 ug/L 0.015 _+20% 0.70 ug/L 0.52 ug/L 94.94 96.27
Test Parameters: pH = 7.5 + 0.5 unless otherwise noted.
Temp. = 68°F to 71.6°F (20°C to 22°C).
It is essential that operational, maintenance, and filter
replacement requirements be carried out for the product to
perform as advertised.
Model T1KB1 : The filter monitor system measures the amount of
water that passes through the filter and alerts you to replace the
filter.
Style 1 - When the filter indicator reads 10%, order a new filter.
When the filter indicator reads 0%, it is recommended that you
replace the filter.
Style 2 - When the filter indicator light changes from green to
yellow, order a new filter. When the filter indicator light changes
from yellow to red, it is recommended that you replace the filter.
Use replacement cartridge T1RFKB1, part #9020. In Canada, use
replacement cartridge T1RFKB1, part #9020B. 2005 suggested
retail price of $39.99 U.S.A./S59.95 Canada. Prices are subject to
change without notice.
These contaminants are not necessarily in your water supply.
While testing was performed under standard laboratory
conditions, actual performance may vary.
The product is for cold water use only.
Do not use with water that is microbiologically unsafe or of
unknown quality without adequate disinfection before or after the
system. Systems certified for cyst reduction may be used on
disinfected waters that may contain filterable cysts.
*Class I particle size: >0.5 to <1 um
**Test requirement is at least 100,000 particles/mL of AC Fine Test Dust.
tfFibers greater than 10 um in length
*Based on the use of Cryptosporidium parvum oocysts
® NSF is a registered trademark of NSF International.
Flow = 0.5 gpm (1.9 Lpm). Pressure = 60 psig (413.7 kPa).
Refer to the front cover or "Accessories" section for the
Manufacturer's name, address and telephone number.
Refer to the "Warranty" section for the Manufacturer's limited
warranty.
Application Guidelines/Water Supply Parameters
Water Supply City or Well
Water Pressure 30 - 120 psi (207 - 827 kPa)
Water Temperature 33 ° - 100°F (0.6 ° - 37.8°C)
Service Flow Rate 0.5 gpm (1.9 L/min) @ 60 psi
26