Tools needed for
installation:
pencil
Electrical
requirements
Electrical Shock Hazard
l Electrical ground is required on this
appliance.
l Do Not ground to a gas pipe.
l Do Not have a fuse in the neutral or
grounding circuit. A fuse in the
neutral or grounding circuit could
result in an electrical shock.
l Check with a qualified electrician if
you are in doubt as to whether the
appliance is properly grounded.
Failure to follow these in instructions
could result in serious injury or death.
If codes permit and a separate
grounding wire is used, it is
recommended that a qualified electrician
determine that the grounding path is
adequate.
IMPORTANT:
Save Installation Instructions for
electrical inspector’s use.
cl
A
A three-wire or four-wire, single
phase, 240-volt, 60-Hz, AC-only
n electrical supply is required on a
separate, 40-ampere circuit, fused
on both sides of the line. A time-delay fuse
or circuit breaker is recommended. The fuse
size must not exceed the circuit rating of the
appliance specified on the serial/rating plate
located on the bottom of the cooktop.
b-l
THE COOKTOP MUST BE
CONNECTED WITH COPPER
n WIRE ONLY.
I I
0
C
Wire sizes and connections must
conform to the requirements of the
. National Electrical Code
ANSVNFPA - latest edition**, or
Canadian Electrical Code, C22.1- 1982, and
C22.2 No. 01982 (or latest edition)*** and
all local codes and ordinances.
Copies of the standards listed may be
obtained from:
**National Fire Protection Association
Batterymarch Park
Quincy, Massachusetts 02269
l ** Canadian Standard Association
178 Rexdale Boulevard
Rexdale (Toronto), Ontario M9W 1 R3
q
D
The appliance should be
connected directly to the fused
. disconnect or circuit breaker box
through flexible, armored or non-
metallic sheathed, copper cable. The
flexible, armored cable extending from the
appliance should be connected directly to
the junction box.
q
E
Locate the junction box to allow as
much slack as possible between
. junction box and the cooktop so
that the cooktop can be moved if
servicing is ever necessary.
Electrical
connection
Electrical Shock Hazard
l Electrical ground is required on this
appliance.
l This appliance must be connected to
a grounded, permanent wiring
system or a grounding connector
should be connected to the
grounding terminal or wire lead on
the appliance.
l Disconnect power to the junction
box.
l Do Not connect to the electrical
supply until appliance is
permanently grounded.
Failure to do so could result in
electrical shock, serious injury, or
death.
This appliance is manufactured with a frame
connected, green or bare grounding wire.
Connect the appliance cable to the junction
box through the U.L.-listed conduit
connector. Complete electrical connection
according to local codes and ordinances.
Where local codes permit
connecting the frame-grounding
conductor to the neutral (white)
junction box wire:
cable from
power supply
Where local codes Do Not permit
connecting the frame-grounding
conductor to the neutral (white)
junction box wire:
cable from power supply
cable from cooktop
Ungrounded neutral
U.i.- or C&A.- listed
conduit connector
cable from cooktop
Grounded neutral
Figure 1
1. Disconnect power supply.
2. Connect the flexible armored cable from
the cooktop to the junction box using a
U.L.- or C.S.A.-listed conduit connector.
Tighten screws on conduit connector.
3. Connect the green (or bare) appliance
cable wire with the neutral (white) wire in
the junction box using twist-on connector.
4. Connect the two black wires together;
then connect the two red wires together
with twist-on connector. (See Figure 1.)
Figure 2
1. Disconnect power supply.
2. Connect the flexible armored cable from
the cooktop to the junction box using a
U.L.- or C.S.A.-listed conduit connector.
Tighten screws on conduit connector.
3. Connect the two black wires together;
then connect the two red wires together
using twist-on connector. (See Figure 2.)
4. Connect the green or bare grounding
wire from the appliance cable to the
grounded wire in the junction box or other
grounded connector using twist-on
connector.
5. Put a twist-on connector on end of white
wire.
6. Contact a qualified electrician to assure
that grounding path is adequate.
7. Do Not ground to a gas supply pipe or
hot water pipe. Do Not connect to
electrical supply until appliance is
permanently grounded.
A U.L.- or C.S.A.-listed conduit
connector must be provided at
each end of the power supply cable
(at the appliance and at the
junction box).
Panel B