Part No. 8285418
© 2003 KitchenAid.
® Registered Trademark/Trademark of
KitchenAid U.S.A., KitchenAid
Canada licensee in Canada
Prepared by KitchenAid, Benton Harbor, Michigan 49022
Printed in U.S.A.
®
SWITCHES ON VALVES
Electric circuit closed when knob is rotated 55°
to 95° counter clockwise from off, except for
TripleTier switch which is closed when TripleTier
knob is rotated 40° to 75° counter clockwise
Caution: Label all wires prior to disconnection when servicing controls.
Wiring errors can cause improper and dangerous operation.
Verify proper operation after servicing.
IGNITOR
ELECTRODES
TT.B.
SWITCH
O, Y OR BR
5 PLACES
SPARK
MODULE
GROUND
GR OR GR/ Y
GROUND
ROUND BLADE
LINE
1/4 WIDE BLADE
NEUTRAL
5/16 WIDE BLADE
PLUG
120 VAC 60 Hz
1 PHASE
15 OR 20 AMP
THE POWER CORD ON THIS APPLIANCE IS EQUIPPED
WITH A THREE PRONG (GROUNDING) PLUG WHICH
MATESWITH STANDARDTHREE PRONG (GROUNDING)
WALL RECEPTACLES
VALVE
SWITCHES
BK RIB
BK
BK
CONNECT
.250 TERMINALS
BK
GR
36" (91.4 cm) Pro Line
™
Series Commercial Style
Cooktop wiring diagram