4
Countertop opening and clearance
dimensions that are shown must be
used. Given dimensions provide required
clearances.
Mobile home installation: The
installation of this cooktop must conform
to the Manufactured Home Construction
and Safety Standards, Title 24 CFR, Part
3280 (formerly the Federal Standard for
Mobile Home Construction and Safety;
Title 24 HUD part 280); or when such
standard is not applicable, the Standard
for Manufactured Home Installations
(Manufactured Home Sites, Communities
and Setups), ANSI A225.1 — latest
edition*, or with local codes.
Cabinet and Cutout Dimensions
18" (45.7 cm) min.
clearance upper
cabinet to countertop
B
min.*
13" (33 cm) max.
upper cabinet depth
3/4" (1.9 cm)
6-7/8" (16.1 cm)
12-5/16" (31.3 cm)
min. clearance to
side wall -
both sides
notch to be equal
both sides.
see corner
notch detail
CORNER NOTCH
DETAIL
4-3/4"
(12.1 cm)
2"
(5.1 cm)
24"
(61 cm)
base cabinet
7-1/4"
(18.4 cm)
C
C
A
D
E
D
E
backguard cabinet and
island trim backguard island trim backguard opening countertop countertop only
5" 1-3/4" 48" (121.9 cm) 36" 35-1/4" 36" (91.4 cm) or
(12.7 cm) (4.4 cm) (91.4 cm) (89.5 cm) 35-7/8" (91.1 cm)
for zero clearance fit
Dimensions are to a combustible surface.
*Note: Dimension “B” can be reduced by 6” (15.2 cm) when bottom of wood or metal cabinet is protected by not less than
1/4” (0.64 cm) flame retardant millboard covered with not less than No. 28 MSG sheet steel, 0.015” (0.4 mm)
stainless steel, 0.024” (0.6 mm) aluminum or 0.020” (0.5 mm) copper.
In Canada, the installation of this cooktop
must conform with the current standards
CAN/CSA-Z240 — latest edition**, or with
local codes.
The cooktop is designed to hang from the
countertop by its side and rear flanges.
The gas and electric supply should be
located as shown in “Gas and Electric
Dimensions,” Page 5, so that they are
accessible without requiring removal of
the cooktop.
Provide cutout in left rear corner of cutout
enclosure as shown to provide clearance
for gas inlet, power supply cord, and to
allow the rating label to be visible.
Copies of the standards listed may be
obtained from:
* National Fire Protection Association
One Batterymarch Park
Quincy, Massachusetts 02269
** CSA International
8501 East Pleasant Valley Rd.
Cleveland, Ohio 44131-5575
AB (min.)* C D E
22-1/4"
(56.5 cm)