Kobe Range Hoods CX1830GS-8 Ventilation Hood User Manual


 
5
INSTALLATION
PLEASE READ ENTIRE INSTRUCTIONS BEFORE PROCEEDING
Calculation before Installation
To calculate installation, please refer to Table 1. (All calculation in inches.)
Preparations before Installation
NOTE: TO AVOID DAMAGE TO YOUR HOOD, PREVENT DEBRIS FROM ENTERING
THE VENT OPENING.
- Decide the location of the venting pipe from the hood to the outside. Refer to Figure
1.
- A straight, short venting run will allow the hood to perform more efficiently.
- Try to avoid as many transitions, elbows, and long run as possible. This may reduce
the performance of the hood.
- Use duct tape to seal the joints between pipe sections.
- If necessary, prepare back wall frame with cross framing lumber for secure installation.
Using references in Table 1 and measurements on page 15, decide the level of the
lumber. Refer to Figure 2.
- Important: peel protective film off the duct cover and the hood (if any).
TABLE 1
A = Height of Floor to Ceiling
B = Height of Floor to Counter
Top (Standard: 36”)
C = Preferred Height of Counter Top to
Hood Bottom (Recommended 27”
to 30”)
D = Height of Hood
E = Height of the Hood
Installation [A – (B + C)]
F = Height of Duct Cover [E – D]
SAFETY WARNING
HOOD MAY HAVE VERY SHARP EDGES; PLEASE WEAR PROTECTIVE GLOVES IF
REMOVING ANY PARTS FOR INSTALLING, CLEANING OR SERVICING.