Kuppersbusch USA GKS 6740.0 M-UL Cooktop User Manual


 
14
ADJUSTMENTS
FIG. 13
Always disconnect the appliance from the
electricity main before making any adjustments.
All seals must be replaced by the technician at
the end of any adjustments or regulations.
Our burners do not require primary air
adjustment.
11) TAPS
“Reduced rate” adjustment
- Switch on the burner and turn the relative knob to
the “Reduced rate” position (small flame fig. 1).
- Remove knob “M” (fig. 13) of the tap, which is
simply pressed on to its rod.
- Insert a small screwdriver “D” into hole “C” (fig. 13)
and turn the throttle screw to the right or left until
the burner flame has been adequately regulated to
the “Reduced rate” position.
Check that the flame does not go out when the
knob is sharply switched from the “Full on” to the
“Reduced rate” position.
It is understood that only burners operating
with Natural Gas or Town gas should be
subjected to the above mentioned adjustments.
The screw must be fully locked when the
burners operate with Propane HD-5 (turn
clockwise).
In the case of a “DUAL” burner, the regulation
screw situated inside the post of the valve regulates
the central flame, while the screw next to the valve
regulates the outer flame.
The operations described above can be carried out
easily, whatever the position of the hob or however
it is fastened to the unit.
THE BURNERS DO NOT REQUIRE ANY
REGULATION OF THE PRIMARY AIR.