Liebherr EWTNes 2956 Beverage Dispenser User Manual


 
A delight in freshness
WF1051 / EWTNes 2956
15
INSTALLATION
1.
At least 31 square inches (200cm
)
1
2
1 1/2”
(38mm)
2
0
3
/4
(
5
2
7
m
m
)
2
2
1
5
1/2"
(13 mm)
24"
(609.6 mm)
3-11/16"
(93,7 mm)
The following ventilation cross-section and
distances must be observed:
- There must be a ventilation space of at
least 31 square inches (200 cm²) per
appliance in the cabinet plinth and under
the cabinet top panel.
- The depth of the ventilation duct at the
rear of the cabinet must be at least 1-
1/2" (38 mm).
Alternatively:
1. For built-in appliances without
ventilation grilles and only with an
installation frame, ventilation must take
place through the ventilation duct at the
rear of the cabinet.
Built-in appliances with an installation frame:
Figure 19:
- Screw the complete installation frame (2)
to the appliance.
2. Built-in appliances with a wooden
ventilation grille:
Figure 20: Cut out the wooden trim for use
as a ventilation grille using the enclosed
template.
- The required ventilation cross-section
must be at least 31 square inches
(200 cm²) when a single appliance is
installed, which corresponds to template
“small” (If you install two appliances
side-byside, the cross-section must be at
least 62 square inches, (400 cm²), which
corresponds to template “double-size;”
for more information see “Side-by-Side
Installation”).
Remove the attachment bracket (2) from
the installation frame and screw it to the
appliance (1) from underneath. Place
the wooden ventilation grille (5) on the
appliance, align it in the center and secure
it from the rear using the attachment
bracket (2).
Figure 19
Figure 20