Impinger I – Operator Manual
13
RESTRAINT REQUIREMENT – GAS OVEN(S) ON CASTERS, U.S. AND AUSTRALIA
1. The installation shall be made with a gas connector that complies with the Standard for Connectors for Movable
Gas Appliances, ANSI Z21.69 latest version, and a quick disconnect device that complies with the Standard for
Quick Disconnect Devices for Use With Gas Fuel, ANSI Z21.41 latest version.
IN CANADA: The installation shall be made with gas connectors that comply with Canadian Code CSA 6.16
latest version and quick disconnects complying to Canadian Code CSA 6.9 latest version.
IN AUSTRALIA: To be installed in accordance with AS 5601-2004 and 4563-2004 Gas Installation Code.
2. The installation of the restraint must limit the movement of the oven(s) without depending on the connector, the
quick disconnect device or its associated piping to limit the oven movement.
3. If the restraint must be disconnected
during maintenance or cleaning, it must
be reconnected after the oven has been
returned to its originally installed
position.
OPERATIONS
1. Screw lifting eye “B” of cable assembly
to hole “A”.
2. Screw eye bolt “C” of cable assembly to
stud in wall “D” or floor anchor “E”.
NOTE: Installation point is the same for
single and double stack oven(s).
PROGRAMMING
(QUEST UNITS ONLY)
Quest EMS Energy Management System by Lincoln Foodservice Products is a unique energy saving system
designed to optimize the performance of a gas or electric powered burner focused to save 40% to 65% energy at
idle conditions. Significant energy savings for accelerated impingement ovens are achieved through the
complementary effects of reduced fan rpm, optimized burner or electric control settings, and reduced volume
impingement air flow.
QUEST OPERATING INSTRUCTIONS
1. Press button on control box side panel to illuminate button and engage the Quest energy savings option.
The oven is now in energy savings mode.
2. To bring the oven out of energy savings mode, simply press the button again to allow for normal operation.
Notice that with the oven back in normal operating mode, the side panel button is no longer illuminated.
NOTE: When starting up the oven after the Quest system has been installed, the main fan may take upwards
of sixty seconds to begin running. This is normal operating procedure.
BACK OF DOUBLE OVEN
WALL
STUD
FLOOR