Burner Performance
CAUTION: Never cover control knobs or surrounding
control surface with utensils, towels, or other objects.
Never obstruct free air passage past the control knobs.
The knob openings have been sized to properly control air
entry to the interior of the appliance during operation.
This appliance has no air shutters. Primary air
adjustments are unnecessary. The burners a re designed
to provide optimum aeration for all gases without air
shutters. When operating properly, burners should
produce clearly defined, even blue flames. If the flames
have yellow tips or are hazy and otherwise appear to
have insufficient air, obtain the services of a qualified
service technician. Some yellow tipping on LP gas is
normal.
Specified input rates are as shown in figures 15 and 16
below.
BURNER LOCATION Hi Lo
Right Front 12,500 / 10,500 1300 / 1300
Right Rear 9,200 / 9,100 1300 / 1300
Left Front 9,200 / 9,100 1300 / 1300
Left Rear 9,200 / 9,100 1300 / 1300
C e n t e r -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- --
INPUT RATES - NATURAL GAS / LP GAS (BTU/HR)
FIGURE 15
5 BURNER MODEL (36 Wide)
30 Cooktop
FIGURE 16
36 Cooktop
BURNER LOCATION Hi Lo
Right Front 12,500 / 10,500 1300 / 1300
Right Rear 9,200 / 9,100 1300 / 1300
Left Front 9,200 / 9,100 1300 / 1300
Left Rear 10,500 / 9,100 1300 / 1300
Center 9,200 / 9,100 1300 / 1300
INPUT RATES - NATURAL GAS / LP GAS (BTU/HR)
4 BURNER MODEL (30 Wide)
High Altitude Notice
The specified gas burner ratings typically apply to
elevations up to 2000 feet. For higher altitudes, the rates
may need to be reduced to achieve satisfactory operation.
A local certified gas servicer will be able to advise if a
reduction is necessary.
Reviewed by Stewart, Steven | Released