Electrical
All cord-connected units must be plugged into a
grounded and properly sized electrical outlet with
appropriate overcurrent protection. Refer to the drawing
below for electrical plug configurations.
5-20P and 5-15P Electrical Plug Configurations
All permanently connected (hard wired) units are fitted
with a power junction box and 6" pigtail wires for power
connection.
Connect one end of the power line to the pigtail from the
cabinet junction box. Connect the other end to a properly
sized electrical source.
As a rule, the power lines must be enclosed inside a
conduit secured to the power junction boxes on both
ends.
NOTE: Power installation must be in compliance with the
National Electrical Code and all applicable local and
state codes.
After the power source has been connected, turn on the
main power switch. The switch is located on the cabinet
top, behind the front louvered panel.
SER.4
5-15P5-20P
!
Warning
Never use an extension cord.
Never alter the power cord or plug supplied with the
cabinet. Failure to follow this warning could result in
serious injury or death.