Manitowoc Ice Q Ice Maker User Manual


 
Section 4 Maintenance
Part Number 000001114 4-9
4. Straighten any bent condenser fins with a fin comb.
Straighten Bent Condenser Fins
5. Carefully wipe off the fan blades and motor with a
soft cloth. Do not bend the fan blades. If the fan
blades are excessively dirty, wash with warm, soapy
water and rinse thoroughly.
Water-Cooled Condenser
and Water Regulating Valve
Symptoms of restrictions in the condenser water circuit
include:
Low ice production
High water consumption
High operating temperatures
High operating pressures
If the ice machine is experiencing any of these symptoms,
the water-cooled condenser and water regulating valve
may require cleaning due to scale build-up.
Because the cleaning procedures require special pumps
and cleaning solutions, qualified maintenance or service
personnel must perform them.
AlphaSan
®
The goal of AlphaSan
®
is to keep the plastic surfaces of
an ice machine cleaner, by reducing or delaying the
formation of bio-film. The active ingredient in AlphaSan
®
is the element silver in the form of silver ions (Ag+).
AlphaSan
®
slowly releases silver ions via an ion
exchange mechanism. When AlphaSan
®
is
compounded directly into a plastic part, a controlled
release of silver ions from the surface is regulated to
maintain an effective concentration at or near the
surface of the plastic ice machine part. AlphaSan’s
®
unique ability to effectively control the release of silver
not only protects against undesired discoloration of the
plastic, but also will last the life of the plastic part.
Although AlphaSan
®
helps prevent bio-film build up it
does not eliminate the need for periodic cleaning and
maintenance. AlphaSan
®
has no adverse effect on the
taste of the ice or beverage.
!
Caution
If you are cleaning the condenser fan blades with
water, cover the fan motor to prevent water damage
and disconnect electrical power.
SV1515
FIN
COMBS
CONDENSER
“COMB” DOWN
ONLY