Manitowoc Ice STH003 Ice Maker User Manual


 
69
REFRIGERANT RE-USE POLICY
Manitowoc recognizes and supports the need for
proper handling, re-use, and disposal of, CFC and
HCFC refrigerants. Manitowoc service procedures
require recapturing refrigerants, not venting them to the
atmosphere.
It is not necessary, in or out of warranty, to reduce or
compromise the quality and reliability of your
customers’ products to achieve this.
IMPORTANT
Manitowoc Ice, Inc. assumes no responsibility for
use of contaminated refrigerant. Damage resulting
from the use of contaminated, recovered, or
recycled refrigerant is the sole responsibility of the
servicing company.
Manitowoc approves the use of:
1. New Refrigerant
Must be of original nameplate type.
2. Reclaimed Refrigerant
Must be of original nameplate type.
Must meet ARI Standard 700 (latest edition)
specifications.
3. Recovered or Recycled Refrigerant
Must be recovered or recycled in accordance
with current local, state and federal laws.
Must be recovered from and re-used in the
same Manitowoc product. Re-use of recovered
or recycled refrigerant from other products is not
approved.
Recycling equipment must be certified to ARI
Standard 740 (latest edition) and be maintained
to consistently meet this standard.