INSTALLING YOUR REFRIGERATOR
4
Front
Leveling Legs
Front Grille,
keep this area
open.
Figure 2
Select Location
The proper location will ensure peak performance of your
appliance. We recommend a location where the unit will
be out of direct sunlight and away from heat sources. To
ensure your product performs to specications the recom-
mended installation location temperature range is from 55
to 100°F (13 to 38°C).
Outdoor Installation
Only the 3OARM & 6AROM models are suitable for outdoor
installations
Building codes may require a ground fault circuit interrupter
electrical receptacle to supply electrical power to the refrig-
erator for outdoor applications, (see "Electrical Connection"
section).
Do not install in a location where the unit will be exposed
to direct sun exposure as this may result in unsatisfactory
performance.
Cabinet Clearance
Ventilation is required from the bottom front section of the
unit. Keep this area open and clear of any obstructions.
Adjacent cabinets and counter top can be installed around
the unit as long as the front grille and remains unobstruct-
ed.
Leveling Legs
Adjustable legs at the front and rear corners of the unit
should be set so the unit is rmly positioned on the oor
and level from side to side and front to back. The overall
height of your Marvel refrigerator may be adjusted between
the minimum (by turning the leveling leg in) and the maxi-
mum (by turning the leveling leg out) dimensions as shown
in Table A.
To adjust the leveling legs, place the refrigerator on a solid
surface and protect the oor beneath the legs to avoid
scratching the oor. With the assistance of another person,
lean the refrigerator back to access the front leveling legs.
Raise or lower the legs to the required dimension by turn-
ing the legs. Repeat this process for the rear by tilting the
refrigerator forward using caution to prevent the door from
opening. On a level surface check the refrigerator for level-
ness and adjust accordingly.
The front grille screws may be loosened and the front grille
adjusted to the desired height. When adjustment is com-
plete tighten the front grille screws. (See Figure 3).
Front Grille
Do not obstruct the front grille. The openings within the
front grille allow air to ow through the condenser heat ex-
changer. Restrictions to this air ow will result in increased
energy usage and loss of cooling capacity. For this reason
it is important this area to not be obstructed and the grille
openings kept clean. AGA MARVEL does not recommend
the use of custom made grilles as air ow may be restricted
because of inadequate openings. (See Figure 2).
Rear
Leveling legs
Table A
Model Minimum
Height
Maximum
Height
30ARM,3OARM,
61ARM,6ADAM
33
3
⁄4
(85.7cm)
34
3
⁄4
(88.3cm)
6ARM,6ARCM
6AROM
MPRO6ARM
33
7
⁄8
(86.1cm)
34
7
⁄8
(88.7cm)