Maytag MGR6775ADB/Q/S/W Double Oven User Manual


 
Testing Procedures
!
WARNING
To avoid risk of electrical shock, personal injury or death; disconnect power and gas to oven before servicing,
unless testing requires power and/or gas.
©2004 Maytag Services 16023415 19
Illustration/Component Test Procedure Results
Control Panel Assembly
Model MGR6875AD*
Continuity is indicated as follows:
1000 – 6600 for Cancel pad
1000 – 10000 for All other pads
Pad
1
2
3
4
5
6
7
8
9
0
Lower Cancel
Upper Cancel
Conv Bake
Delay
Clock
Favorite
Lower Clean
Upper Clean
Lower Bake
Lower Light
Upper Keep Warm
Upper Light
Autoset
Lower Keep Warm
Conv Roast
Upper Bake
Timer 2
Cook & Hold
Upper Broil
Timer 1
Trace
14 & 16
17 & 16
16 & 8
7 & 6
8 & 17
7 & 14
6 & 15
5 & 14
6 & 14
8 & 14
1 & 2
11 & 12
4 & 15
5 & 6
5 & 16
5 & 7
5 & 15
7 & 16
8 & 15
7 & 15
7 & 17
15 & 16
14 & 17
8 & 16
5 & 4
4 & 14
4 & 7
6 & 16
14 & 15
4 & 16
Measurement
Continuity
Continuity
Continuity
Continuity
Continuity
Continuity
Continuity
Continuity
Continuity
Continuity
Continuity
Continuity
Continuity
Continuity
Continuity
Continuity
Continuity
Continuity
Continuity
Continuity
Continuity
Continuity
Continuity
Continuity
Continuity
Continuity
Continuity
Continuity
Continuity
Continuity
Model MGR6775AD* Membrane and Overlay