Middleby Marshall PS528G Oven User Manual


 
SECTION 2
INSTALLATION
17
If the installation will use the supplied gas hose, be sure that the
1/2"to3/4"gaslinettingisattached.Refertotheinstructions
in the gas hose package. One gas line connection method is
shown in Figure 2-15; however, compliance with the applicable
standards and regulations is mandatory.
Inlet and regulated gas pressures can be measured using
a “U” tube manometer at the tap locations shown in Figures
2-15 and 2-16.
1. Checking the Gas Supply (Inlet) Pressure
a. With the main gas supply valve closed and the circuit
breaker/fused disconnect in the OFF ("O") position, open
the inlet pressure tap shown in Figure 2-16 and attach a
manometer to the tap.
b. Depress the safety switches to allow the oven to
operate.
c. Open the main gas supply valve. Switch the circuit breaker/
fused disconnect to the ON ("I") position.
d. Start the oven according the directions in the Operation
section of this Manual. Adjust the temperature controller
tothemaximumsetting(316°C).
e. Measure the supply (inlet) pressure.
f. Switch the oven off. Close the main gas supply valve,
and switch the circuit breaker/fused disconnect to the OFF
("O") position. Remove the manometer, and close the inlet
tap.
g. Compare the measured supply (inlet) pressure to the
nominal pressures shown in Table 1-5 (in the Description
section of this Manual).
If the supply pressure is lower or higher than the nominal
pressure, the reason should be investigated and the gas
supplier contacted.
For natural gas ovens, if the measured supply pressure is lower
than 0.247psi, or higher than 0.363psi, contact the gas supplier.
DO NOT OPERATE THE OVEN or adjust the oven controls.