Miele 09 813 750 Ventilation Hood User Manual


 
Installation
40
Secur
e the exhaust socket to the
hose using a hose clip.
Secur
e the hose to the directional
unit socket using a hose clip.
Che
ck that the hose is held securely.
P
ush the telescopic piece over the
installation frame:
with the recirculation grilles at the
bott
om for air extraction mode (AL)/
external motor (EXT),
with the recirculation grilles at the top
for r
ecirculation mode (UL).
Bend the two r
etaining tabs outwards
to prevent the telescopic piece from
slipping down again.