Miele 09 898 161 Range User Manual


 
All Gas Range dimensions
33
HR 1135, HR 1136
Position Dimension Description
Ǟ
min. 36"
(914 mm)
Width of cabinet opening
ǟ
6“ + Ǟ + 6" In case of the presence of combustible material an
additional minimum clearance of 6“ (each side) is
necessary. Ensure local codes are observed.
Ǡ
37" (940 mm) Minimum distance between the top of the cooking
area and the bottom of an unprotected
combustible surface.
30" (762 mm) Minimum distance between the top of the cooking
area and the bottom of the Miele Range Hood
(DAR model with DRxB XL or DRxB XXL Blower).
For all other Hoods, please consult with manufacturer's instructions
for required distances.
ǡ
approx. 13 3/4"
(350 mm)
Maximum connection width right
and left
Location of
wall
receptacle
Ǣ
approx. 4 1/2"
(115 mm)
Maximum connection height
ǣ
approx. 2 13/16"
(72 mm)
Maximum connection depth
The hatched areas represent the installation areas for the connections.
12" (305 mm) minimum distance is necessary from back of range to combustible rear wall
above countertop.