Miele CVA 615 Coffeemaker User Manual


 
If an error occurs a fault message will appear. With the following guide, minor
problems can be fixed without a service call.
Message Possible fault Fix
Fill coff. beans
Ready for use
Coffee bean container is empty. Refill with coffee beans.
Brew unit block. The brew unit is clogged. Clean the brew unit.
Brew unit miss. The brew unit is not properly seated. Take out the brew unit and reseat.
Descale The unit needs to be descaled. Descale the unit.
Expel air Air has built up in the system. The unit
is blocked.
Fill the water tank.
Turn the program selector to "On with
light" and place containers below the
hot water dispenser and the steam
nozzle.
Press the hot water button, turn the
steam selector counterclockwise
and let water run out until it streams
steadily.
Press the hot water button again.
Turn the steam selector to "o" to shut
off the water.
Fresh water? A reminder to fill the water tank with
fresh water.
Waste unit miss. The waste unit is missing or not seated
properly.
Return or reposition the waste unit.
Empty waste unit
press ENTER.
The waste unit is full. The system will
not dispense coffee until the waste unit
is emptied.
Empty waste unit and press ENTER.
Energy-save
mode . . .
press ENTER
The unit is in the energy-save mode.
Light is off.
Press ENTER.
Watersystem
fault
There is a problem in the water lines. Call Miele Technical Service.
Fill watertank The water tank is empty or missing or
the float in the water tank is stuck.
Empty water tank, rinse, fill with fresh
water and replace.
Fault messages
47