If the exhaust is ducted into an
inactive flue, the air must be expelled
parallel to the flow direction of the
flue.
Never connect an exhaust hood to
an active chimney, dryer vent, flue,
or room venting ductwork. Seek
professional advice before
connecting an exhaust hood vent to
an existing, inactive chimney or vent
flue.
Important
If the ductwork runs through rooms,
ceilings, garages, etc. where
temperature variations exist, it may
need to be insulated to reduce
condensation.
Condensate trap
optional accessory
In some cases, a 2 condensate traps
may be required to collect and
evaporate any condensation which may
develop. This optional accessory is
available for ducts 5" (125 mm) and
5
7
/
8
" (150 mm) in diameter.
^ When installing the condensate traps,
ensure that they are positioned
vertically and if possible directly
above the exhaust outlet.
Air extraction
29