Miele DA5341D Ventilation Hood User Manual


 
All electrical work should be
performed by a qualified electrician
in strict accordance with national
and local safety regulations.
Installation, repairs and other work
by unqualified persons could be
dangerous. The manufacturer can
not be held responsible for
unauthorized work.
Ensure that power to the appliance
is OFF while installation or repair
work is performed.
^
Verify that the voltage, load and
circuit rating information found on the
data plate (located behind the
grease filter), match the household
electrical supply before installing the
hood.
^ This appliance requires two electrical
mains cables. Each one must be
connected via a suitable isolator
which complies with local and
national safety regulations. Their
on/off switches must be easily
accessible after the appliance has
been built in.
If there is any question concerning the
electrical connection of this appliance
to your power supply, please consult a
licensed electrician or call Miele’s
Technical Service Department. See
back cover for contact information.
WARNING:
THIS APPLIANCE MUST BE
GROUNDED
Important
To increase security before the
machine is installed, it is
recommended to install a protective
switch (30 mA).
Important
The hood must be hard wired
accordingly:
Black/Red wire:....connect to L1 (live)
White wire: .....connect to N (neutral)
Green wire: . . connect to GND (ground)
Maximum load...............820W
Fan....................2x350W
Lighting .................6x20W
Voltage .....................120V
Frequency ..................60Hz
Circuit rating..................15A
Electrical data
30