Miele H 212 E Cooktop User Manual


 
Electrical connection
\}
\
The voltage and rated load are given
on the data plate, visible when the
oven door is open. Please ensure that
these match the household mains sup-
ply.
Underbench oven
The appliance is supplied with a 3-core
cable for connection to a 230-240 volt
50 Hz supply.
The fuse rating is 32 amps for the "E"-
model with hob.
Wall oven
The appliance is supplied with a 3-core
cable for connection to a 230-240 volt
50 Hz supply.
The fuse rating is 13 amps for the "B"-
model.
The wires are coloured in accordance
with the following code:
Green/yellow = earth
Blue = neutral
Brown = live
WARNING
THIS APPLIANCE MUST BE
EARTHED.
}
Data relating to electrical connection
will be found on the data plate, visible
when the oven door is open. Make sure
that these figures comply with the main
voltage. Connection should be made
via a suitable isolator which complies
with national and local regulations.
Underbench oven
The appliance is supplied with a 3-core
cable for connection to a 230-240 volt
50 Hz supply.
The fuse rating is 32 amps for the "E"-
model with hob.
Wall oven
The appliance is supplied with a 3-core
cable for connection to a 230-240 volt
50 Hz supply.
The fuse rating is 16 amps for the "B"-
model.
The wires are coloured in accordance
with the following code:
Green/yellow = earth
Blue = neutral
Brown = live
WARNING
THIS APPLIANCE MUST BE
EARTHED.
56