Ventilation
Air at the back of the appliance gets
warm. The appliance housing unit must
be constructed to allow sufficient space
for ventilation.
A ventilation gap of at least 38 mm
depth must be allowed for behind the
appliance for air to circulate.The air
inlet to the appliance is via the plinth in
the housing unit.
The cross-section of the air inlet and
outlet must be at least 200 cm
2
to
ensure that air can circulate without
hindrance. Otherwise the appliance has
to work harder, resulting in an increase
in electricity consumption.
The air inlet and outlet must not be
covered or blocked in any way.
They should be dusted on a regular
basis.
Before installation
^ Before installation, remove the cover
strip, sealing strip and other
accessories from the appliance and
from the external rear wall of the
appliance.
^
On no account should the spacers
be removed from the back of the
appliance. These ensure the gap
required between the back of the
appliance and the wall is maintained.
^
Remove any cable clips from the rear
of the appliance.
^ Remove the red transport fixing a,
and use the stopper supplied b to
plug the empty hole.
^ Check that all parts at the back of the
appliance are unhindered. Carefully
remove any hindrance.
Does your old appliance have
a different hinging
mechanism?
If your old appliance had a different
type of hinging, the furniture door can
still be used. Remove the old hinges
from the housing unit. They are no
longer required because the furniture
door is now fitted to the appliance door.
All the necessary parts are supplied or
can be ordered from the Miele Spare
Parts Department.
Installation
47