The machine must be connected to
the water supply by a licensed
plumber in accordance with local
and national regulations. The water
being used should have the drinking
water standards of the respective
country where the machine is used.
All units and systems used to deliver
the water to the appliance must
conform with the requirements of the
respective country.
The machine is designed to be
plumbed to a cold water connection.
The on-site water line must have a
water valve to turn the water off if
needed. If not present, have a water
valve installed by a licensed
plumber.
The water valve must be accessible
after installation.
Water pressure on-site:
Minimum: 14.5 psi
Maximum: 145 psi, if higher, install a
pressure reduction valve.
Suitable 1/4" tubing or copper piping
must be supplied for plumbing.
To ensure the best ice cube quality,
the maximum length of the tubing or
copper pipe should not exceed 4 ft.
11" (1.5 m). If too much water
remains in the tubing the quality
could be affected.
Connecting to the water
supply
^
Disconnect the machine from the
electrical supply.
^
Remove the cover cap a from the
solenoid valve b.
^
Install the compression fitting c with
the sealing ring d on the solenoid
valve b.
^
Attach the copper line e to the
compression fitting c.
^
Secure the copper line to the
appliance using cable clips f.
Plumbing (may vary by model)