Miele KM83-2 Cooktop User Manual


 
Gas connection
This appliance must be installed
with a separate shut-off valve and a
gas pressure regulator (included).
Both shut-off valve and pressure
regulator must be easily accessible
to the consumer.
This appliance and its individual
shut-off valve must be discon-
nected from the gas supply system
during any pressure testing of that
system.
For USA only
The gas connection must be made
in accordance with local codes, or
in absence of local codes, with the
National Fuel Gas Code,
ANSI Z 223.1-1980.
Gas Pressures for USA
Max. Supply Pressure: 1/2 PSI
Manifold pressure:
– Natural gas – 4" water column
– Propane gas – 10" water column
For CDN only
The gas connection must be made
in accordance with local codes, or
in absence of local codes, with the
current CAN/CGA B 149.1 and .2
Inst.
Gas Pressures for CDN
Manifold pressure:
– Natural gas 4" water column
– Propane gas 10" water column
Pressure regulator
A pressure regulator convertible from
Natural to LP Gas is included with this
appliance.
Conversion is carried out by inverting
the regulator cap marked "NAT"/"LP". If
"NAT" is visible then the regulator is set
for Natural and if "LP" is visible then set-
ting is for Liquefied Petroleum Gas (Pro-
pane).
Nominal rating for all types of gas on
the high setting
kW Btu/hr
Normal burner
Fast burner
1.65
2.70
5630
9212
Nominal rating on the low setting
Type of gas kW Btu/hr
Normal burner Natural gas
LP gas
0.26
0.26
887
887
Fast burner Natural gas
LP gas
0.45
0.54
1535
1842
Gas connection
18