Moffat ESV5060W Cooktop User Manual


 
16011105/R3
19
ELECTRICAL CONNECTIONS
Any electrical work required to install this
hob should be carried out by a qualified
electrician or competent person, in accordance
with the current regulations.
THIS COOKER MUST BE
EARTHED.
The manufacturer declines any liability
should these safety measures not be
observed.
This cooker is designed to be
connected to a 230-240V 50Hz AC
electrical supply.
Before switching on, make sure the electricity
supply voltage is the same as that indicated on
the hob rating plate. The rating plate is located
on the bottom of the
hob.
The cooker is supplied without a supply cord. A
supply cord must be fitted, in accordance with
the specification given in the relevant tables.
1. Loosen the two fixing screws securing the
back protective screen of the cooker, then
lift it up and remove it. This will expose the
terminal block on the right bottom corner.
2. Loosen the two cable clamp screws and lift
the top section of the clamp enough to allow
the cable to be passed through.
3. Connect the red (live) wire to the terminal
which is marked with the letter "L".
4. Connect the black (neutral) wire to the
terminal which is marked with the letter "N".
5. After fitting a green or yellow/green sleeve
over the bare copper wire (earth wire),
connect the exposed end to the terminal
which is marked with the earth symbol or
with the letter "E" coloured green and
yellow.
NOTE:
The earth wire should be about 2 cm. longer
than the live and neutral wires.
6. Secure the cable by means of the clamp
screws and refit the back protective screen.
The cooker should be connected to a double
pole switch with a minimum gap of 3 mm.
between the switch contacts and of a type
suitable for the required load in compliance with
the current electric regulations. The switch
should be sited within 2m of the hob and be
easily accessible upon completion of the
installation.
The switch must not break the yellow and green
earth cable at any point.
Ensure that the hob supply cord does not
come into contact with surfaces with
temperatures higher than 50 deg.C.
Supply Cable Specifications
For UK use only
Connection
Via
Min. size
Cable
Fuse
Cooker
Control
Circuit
6 mm²
Twin &
Earth
30 A
For European use only
Min. Size
Cable
Cable / flex
type
Fuse
3 x 2.5 mm² H05 W-F 30 A
18
6
5
4
3
2
1