Citizservicemanual
37
O P E R A T I O N
5.5 Emptywatersystem
Aftereveryoperation,somewaterremainsinthecoffeemachine.Thereforethewater
systemmustbeemptied
ifthecoffeemachinewillnotbeusedforalongtime
asantifreezemeasure
forrepairsandshipment.
1) Switchoffcoffeemachine. 2) Removewatertank.
3) Placeabeakerunderthecoffeeout
let.
ModelCitiz&Co:
Onlyonecoreunit
shouldbeemptiedat
thesametime(dangerof
mainssupplyoverload).
Afterthisprocedure,
thecoffeemachine
willnotbereadyfor
approx.10min(untilthe
thermoblockcoolstobelow
100 °C).
4) Pressandholdbutton"smallcup".
5) Switchthecoffeemachineonagain.
6) Releasebutton"smallcup".
Thepumpstartstodrainthewater
systemandstopsautomatically.
Thecoffeebuttonsblinkfastsimulta
neously.
7) Afterautomaticstop,switchoffthe
coffeemachine.