Citizservicemanual
72
R E P A I R S
1. Removegasket(a)fromwatertankconnector(53).
2. Withthehelpofapairoftweezers,removeclampingring(b)andmetalsieve(c).
3. Cleanorreplaceparts.
Assemblycheckpoints
• Checkthatgasketisinsertedinwatertankconnector(53)correctly.
• Duringassemblyofthewatertankconnectorontheplatform,eachofits3latches
hastoengagewithanaudibleclick.
• Mindthedifferentdiametersofhosesforthewatertankconnector.