OK International DX-200/215 Water Dispenser User Manual


 
5
5 CONNECTING THE UNIT
CAUTION: A 5-micron filter (TSD800-6), not included, must be installed with the unit
to ensure proper air filtration.
6 SETUP INSTRUCTIONS
Refer to Figure 1.0
6.1 Manual Dispense Cycle Setting:
1. Turn on the unit by pressing the Power button (1).
2. Press the Mode button (2) until “MANUAL MODE” appears on the
Display.
3. Turn up the air pressure by rotating the Air pressure regulator knob (6)
until the desired pressure is indicated on the Air pressure gauge (5).
4. After filling the barrel or using pre-packaged Adhesives, attach syringe
to receiver head assembly. Make certain that the syringe locks into
place.
5. Connect the plug end of the receiver head assembly to one of the air
dispense outlet (7).
6. If vacuum “suck back” is needed, rotate the Vacuum regulator (8)
counter clockwise until the desired vacuum pressure is obtained
7. Press and hold the Footswitch to activate dispensed cycle. (The Manual
Mode is now activated)
6.2 Automatic Dispense Cycle Setting
1. Push the Mode button (2) to select “TIMED MODE”.
2. Press and hold the Set button (3) for two seconds to enter set up
screen. The last digit of the dispense time will be highlighted.
3. Press the Set button (3) to move the cursor to the next position.
4. Press the (+) and (-) button to set the time
5. Press and hold the Set button (3) for two seconds to save the data.
Items Description
1 To Air Source
2 Air Filter (Not Included)
3 Power Adapter
4 Foot Switch
Figure 2.0
2
1
4
3
6
6. Depress Foot switch to activate timed dispensed cycle.
6.4 Cycle Counter
The cycle counter records the numbers of automatic dispense cycle being
activated. Up to 65,535 cycles can be recorded. This number is shown at
the lower right hand corner of the LCD. To reset the counter, press and
hold the Set button (3) for two seconds to enter the set mode. Then press
and hold the Set button (3) for four seconds to reset the counter.
7 OPERATION DIAGRAM
P1 2.250 00004
OFF
P1 2.250 00004
Normal Operation
Power ON/OFF
MODE
Prog
Time
Counter
Setup
P1 2.250 00004
SETUP MODE
P1 00004
SETUP MODE
P1 00004
Save and Exit...
SETUP MODE
P1 00004
SETUP MODE
P1 00004
SETUP MODE
P1 00004
SETUP MODE
P1 00004
SETUP MODE
P1 00004
SETUP MODE
P1 00004
P1 00004
P1 2.251 00000
2.2
50
22.25
0
22.250
22.25022.25
1
22.25
0
22.251
Save and Exit...
22.251
TIME SETTING
COUNTER RESET
:Press then release :Press and hold for approximately 2 seconds then release
P
OWER MODE SET
Time setting
:Press and hold for approximately 4 seconds then release
TIMED MODE
TIMED MODE
TIMED MODE
in TIMED MODE
TIMED MODE
MANUAL MODE
Change Mode
*************************
TIMED MODE
2.25
1