OK International DX-200/215 Water Dispenser User Manual


 
7
8 TROUBLESHOOTING
PROBLEM POSSIBLE CAUSE CORRECTION
LCD does not
light
No power input
Check power cord
connections
Turn on power
System will not
actuate
Foot switch not
plugged in or
improperly
plugged in
Defective foot
switch
Broken wire or
loose connection
inside unit
Defective
solenoid
Defective PC
board
Check foot switch
connection
Foot switch needs
to be repaired or
replaced
Unplug power cord
and disconnect air
supply. Remove
cover and check
for broken wires or
loose connections
Replace solenoid
Replace PC board
System will not
pressurize
Insufficient air
pressure
Air hoses not
plugged in
Regulator
defective
Increase air supply
pressure
Check connection
Replace regulator
System will not
pull vacuum
Vacuum setting is
too low
Defective
solenoid
Defective
vacuum venturi
Defective
vacuum needle
valve
Increase vacuum
setting
Replace solenoid
valve
Replace venturi
Replace needle
valve
Inconsistent
dispensing
Air bubbles in
Adhesives
Dispense time is
too low
Dispense needle
started to clog
Reduce vacuum
setting
Increase
dispensing time
Replace needle
8
9 MAINTENANCE
The dispenser is designed and built to be relatively maintenance free. To assure
trouble free operation, the following recommendations should be followed:
1. Make certain air supply is clean and dry.
2. Avoid turning barrels upside down or laying barrel so that material may
run through air line to internal components.
3. Avoid connecting the unit to excessive moisture or solvent saturation.
4. Avoid connecting air supply exceeding 100 psi (6.9 bars)
5. Use only Amyl Alcohol to clean outside surface of the main housing.
6. Use only soft cloth to clean the LCD.
10 SPARE PARTS AND ACCESSORIES
For DX-3xx/2xx spare parts and accessories information, please visit the DX-
3xx/2xx User Guide webpage at http://www.okinternational.com
11 LIMITED WARRANTY
OK International warrants this product to the original purchaser for a period of one
(1) year from date of purchase to be free from material and workmanship defects but
not normal wear-and-tear, abuse and faulty installation. Defective product or
subassembly and components under warranty will be repaired or replaced (at OK
International's option) free of charge. Customer with defective product under
warranty must contact the nearest OK International office or distributor to secure a
return authorization prior to shipping the product to the assigned OK International
authorized service center. For nearest OK International office or distributor contact
information, please visit www.okinternational.com. OK International reserves the
right to make engineering product changes without notice.
12 I/O Configuration and End of Cycle Switch
For DX-3xx/2xx I/O Configuration and End of Cycle Switch information, please
visit the DX-3xx/2xx User Guide webpage at http://www.okinternational.com