Parkinson Cowan Libra Cooktop User Manual


 
TECHNICAL DATA
DIMENSIONS
Height Width Depth
Overall 1462mm (nominal) 498mm 600mm
(from elbow
to front of door panel)
Height to hotplate 907mm nominal -
see important note 'Location of the Appliance' (see Page 34).
Space for fixing at hotplate level 2mm minimum 600mm
clearance Nominal
Space for fixing above hotplate level 100mm each side of appliance
Minimum space above grill 500mm
Minimum distance from rear wall 20mm
Weight of appliance 50.0kg
CONNECTIONS
Gas Rear left hand side of appliance at hotplate level
Rc½ (½" B.S.P. female)
Electric None
GRILL
Natural Gas L.P. Gas
Heat Input 3.0kW (10236 Btu/h) 2.75kW (197.5g/h)
Injector Marking 120 80
HOTPLATE
Natural Gas
R.H.F. R.H.R. L.H.R. L.H.F
Heat Input 1.0kW 2.0kW 2.0kW 2.8kW
(3412 Btu/h) (6824 Btu/h) (6824 Btu/h) (9554 Btu/h)
Injector Marking 079 104 104 130
L. P. Gas
R.H.F. R.H.R. L.H.R. L.H.F.
Heat Input 1.0kW 2.0kW 2.0kW 2.7kW
(71.8g/h) (143.7 g/h) (143.7 g/h) (194 g/h)
Injector Marking 51 72 72 83
OVEN
Natural Gas L P. Gas
Heat Input 2.4kW (8189 Btu/h) 2.4kW (172.4g/h)
Injector Marking 108 78
Thermostat By-pass Marking 69 78
28