Perlick H50IMS-L Ice Maker User Manual


 
23
H. Startup
WARNING
1. All parts are factory-adjusted. Improper adjustments may adversely affect
safety, performance, component life, and warranty coverage.
2. If the icemaker is turned off, wait for at least 3 minutes before restarting the
icemaker to prevent damage to the compressor.
3. At startup, conrm that all internal and external connections are free of leaks.
1) Open the water supply line shut-off valve.
2) Make sure the control switch is in the "OFF" position. Plug the unit into the electrical
outlet. If you have to slide the unit back for a built-in installation, make sure you do not
damage or pinch the water supply, drain connections, or power cord.
3) If required by sanitation code in your area, seal the perimeter where the machine
touches the oor with approved caulk compound in a smooth and easily cleanable
manner.
4) Move the control switch to the "ICE" position and allow the icemaker to operate for
2 minutes. This allows the water tank to ll.
5) Move the control switch to the "OFF" position.
6) Inside the storage bin, disconnect the suction tube by squeezing the tabs and pulling
the tube clear. See Fig. 24. Allow the water tank to drain.
7) Reconnect the suction tube as illustrated. See Fig. 25. Make sure the tabs lock into
place; a loose tting may cause a water leak.
8) Clean the storage bin liner, door liner, and door gasket using a neutral cleaner. Rinse
thoroughly after cleaning.
9) Move the control switch to the "ICE" position to start the automatic icemaking process.
10) To conrm bin control operation, hold ice in contact with the bin control thermostat bulb.
The icemaker should stop within 10 seconds.
Water Tank
Drain
Suction Tube
Tabs
Fig. 24 Fig. 25
Suction Tube
Tabs