Pitco Frialator RSCPE14 Pasta Maker User Manual


 
CPE14: ELECTRIC COUNTER MODEL PASTA COOKER PREVENTATIVE MAINTENANCE
L20-274, rev. 0 (1/06) 13
3.3.4. CONTROL BOX & ELECTRICAL COMPONENTS
9 Verify that heating contactors are in good condition. Check for worn or pitted contacts. Verify
that wires are tight and in good condition.
9 Verify that all components (transformer, terminal block, relays, drain switches, etc…) are in
good condition. Verify that wires are tight and in good condition.
9 Verify enclosures are free of leaks. Check for water stains and wet surfaces.
9 Verify that the covers and panels are in tact and provide a safe condition. Check for loose
parts.
9 Verify power cord is in good condition. Check for frayed or exposed wires. Verify that the
insulation is in good condition and the attachment to the appliance is tight.
3.3.5. TANK
9 Verify that the tank is in good condition. Check for scale build up and inspect for signs of
corrosion. Verify that tank is leak free. Check drain overflow (if equipped) for scale build up
and debris blockage.
3.3.6. DRAIN SYSTEM
9 Verify that drain valve is in good condition. Check for leaks in the seal area and fitting region.
9 Verify that drain lines are leak free, kink free and in good condition. Check for scale build up
and debris blockage. Verify that the clamps and connections are securely tightened.