Pitco Frialator RSCPE14 Pasta Maker User Manual


 
TROUBLESHOOTING
14
High Temperature Reset Button
(Not on all models)
4. TROUBLESHOOTING
4.1. POWER FAILURE
If electric power is removed for any reason, the appliance will shut down. To restart the appliance,
follow the appliance start up procedure in section 2.2.
4.2. HIGH TEMPERATURE LIMIT
This appliance is equipped with a high temperature limit switch. The high temperature limit switch will
stop the appliance from functioning if the internal cook tank reaches an unsafe temperature. In the
event that the high temperature limit has tripped, Please refer to the following procedure to reset the
switch.
1. Turn the appliance off.
2. Allow the appliance ample time to cool to room
temperature.
3. Add water to the cook tank as needed.
4. Press the high temperature reset button if equipped.
5. The high limit switch is now reset and the appliance is
ready for start up.
4.3. DRAIN VALVE INTERLOCK
If your appliance is equipped with a drain valve interlock circuit, the appliance will stop heating if the
tank drain valve is opened. In some cases the appliance will turn off. Refer to the following
procedure to resume operation after the drain valve interlock is tripped.
1. Turn the appliance OFF (if not already OFF).
2. Close the tank drain valve and fill the tank with water.
3. Turn the appliance ON.
4.4. CIRCUIT BREAKER RESET
The circuit breaker reset button is located behind the door underneath the front panel. Push the reset
button if it is tripped.
TO ACCESS CIRCUIT BREAKER
WARNING
DO NOT add water to the tank until it has been given ample time to cool down. Failure
to do so may result in damage to the appliance and/or injury to the operator.