Pitco Frialator SSPG14 Pasta Maker User Manual


 
INSTALLATION
10 L20-331, rev.02 (08/11)
FIGURE 1
WARNING
Water must completely cover the heat tubes
at all times while appliance is on.
CAUTION
This appliance is not designed for cooking
with oil. Fill with potable water only.
WARNING
During operation there is an open flame
inside this appliance. The unit may get hot
enough to set near by materials on fire. Keep
the area around the appliance free from
combustibles.
WARNING
If pilot extinguishes, wait 5 minutes before attempting to relight the pilot to allow any excess gas to dissipate.
1.9. INITIAL ADJUSTMENTS
After your appliance has been properly installed as described in the installation section of this manual, it will need to
be adjusted to ensure that it will perform as designed. A qualified person must perform these adjustments.
To perform these adjustments the following tools will be needed:
• Manometer(WC”) • Digital Thermometer (Temperature Probe) • Voltmeter
1.9.1. FILLING THE APPLIANCE
Refer to the following procedure to fill the cook
tank prior to operation.
1. Ensure that the drain valve handle(1) is closed.
2. Fill the tank with water until the water reaches
the water level line, approx. 12 Gals..
1.9.2. LIGHTING INSTRUCTIONS
Refer to the following instructions to light the
appliance.
1. Open the shut off valve (2) for each cooking appliance.
2. Make sure that the appliance is turned OFF, the digital control will display the word “OFF”. If there is
nothing in the controller’s display, make sure the appliance is plugged in to a grounded outlet.
3. Turn the gas valve control knob (3) to the “ON” position. Press the On/Off (I/O) button (4), on the
Digital control once to light the appliance. The matchless ignition system will automatically light the
pilot (5). The first time you start the unit excess air may have to be purged from the gas lines, this may
cause the ignition control to exceed the 90 second ignition cycle. If you hear the ticking of the pilot
stop, turn off the digital control by pressing and holding the (I/O) key (4) for 2 second(s).
4. If the pilot (5) goes out, or does not ignite, wait 5 minutes and repeat step 3. If after three tries the pilot
will not remain lit, refer to the operator troubleshooting section of this manual.
5. Once a pilot flame has been established, the digital control will automatically start the heating cycle.
6. The main burners will light and be controlled by the thermostat after the Self Cleaning Burner cycle.