Rangemaster L 540 720 Ventilation Hood User Manual


 
15
GB
• Replace the lter support
Screw the lter support using the 2 screws 12c (2,9 x 6 ,5) pro-
vided.
• Replace the grease lters make sure that the handle is visible on
the outside.
Connections
DUCTED VERSION AIR EXHAUST SYSTEM
When installing the ducted version, connect the hood to the chimney using either a exible or rigid
pipe ø 150 or 120 mm, the choice of which is left to the installer.
• To install a ø 120 mm air exhaust connection,
insert the reducer ange 9 on the hood body
outlet.
• Fix the pipe in position using suf cient pipe
clamps (not supplied).
Remove any activated charcoal lters.
RECIRCULATION VERSION AIR OUTLET
• Drill a hole ø 120 or 150 mm in the shelf above the hood
and connect the hood canopy outlet to the top part of
the wall unit by means of a rigid or exible pipe of the
same diameter, the choice of which is at the discretion
of the installer.
• To install a ø 120 mm air exhaust connection, insert the
reducer ange 9 on the hood body outlet.
• Fix the pipe in position using suf cient pipe clamps (not
supplied).
Ensure that the activated charcoal lters have been
inserted.
ELECTRICAL CONNECTION
• Connect the hood to the mains through a two-pole switch having a contact gap of at least 3
mm.