COMPONENTS
The chimney hood comprises of the
following: -
No 1 150x120mm ducting spigot (A)
No 1 120x125mm ducting flange (B)
No 1 Canopy (C)
No 2 Recirculation grilles (G)
No 1 Lower chimney stack (I)
No 1 Recirculation ducting (P)
No 2 Recirculation extension ducts (P1)
No 1 Recirculation spigot (R)
No 1 Upper chimney stack (S)
No 1 Valve (V) optional
No 2 Chimney fixing brackets (2)
Please ensure when the appliance is fitted
it is easily accessible to an engineer in the
event of a breakdown.
All installations must comply with
local authorities requirements for
the discharge of exhaust air.
Incorrect installation may affect the
safety of this chimney hood.
INSTALLATION REQUIREMENTS
Before installation check the wall
to which the hood is to be fitted for
electric cables, gas and water
pipes.
This chimney hood is designed to be fixed to
any vertical surface over a cooking area, and
can be used in the extraction (ducted to the
outside) or recirculation mode.
The installation work must be undertaken by
a qualified and competent person.
Leisure Consumer Products disclaims any
responsibility for damage due to incorrect
installation of the chimney hood or if the hood
is not installed in compliance with relevant
regulations controlling this type of installation.
INSTALLING THE CHIMNEY HOOD
10