12
INSTALLATION
Check the appliance is electrically safe when you have fi nished.
Positioning the Oven
The oven can be installed at high level in a tall kitchen unit
and is designed to fi t into a standard 600mm wide oven
housing (Fig.7-1).
The oven is 594mm across the trims and an unrestricted
opening of 540mm minimum depth is needed, as measured
from the front of the cabinet door to the rear of the housing.
Surfaces of furniture and walls adjacent to the appliance
should be heat, splash and steam resistant. All cabinet doors
must be at least 8mm from the oven at all points.
Certain types of vinyl or laminate kitchen furniture are
particularly prone to heat damage and discolouration. We
cannot accept responsibility for damage caused by normal
use of the appliance to any material that de-laminates
or discolours at temperatures less than 65°C above room
temperature.
When placing the oven in the housing, do not use the oven
door as a lever for lifting the oven as damage may result.
Once the oven is in position in the housing, use suitable
screws to secure in place.
50
10
0
15
0
20
0
250
MA
X
0
0
50
100
15
0
200
250
MA
X
0
Fig.7-1
Provision for Ventilation
The appliance housing used must provide adequate
ventilation.
For a built-in installation, a minimum ventilation opening of
500mm x 50mm must be cut into both the top and bottom of
the housing unit to ensure adequate ventilation.
All dimensions in mm