Rayburn 212SFW Cooktop User Manual


 
After completing the installation, the Heating Contractor
should demonstrate to the user, the operation of the
appliance and the routine flue operating method.
1. Check that the system is full of water and free
from air pockets. (Rayburn Cookmaster Plus
212SFW only).
2. Select and install the appropriate burning grate
as required by the customer (see Users
Instructions for method).
3. When lighting pull the flue chamber damper open
to maximum.
4. Add paper and sticks with a small quantity of fuel
through the fuelling aperture onto bottomgrate
and close the firebox door.
5. Open ashpit door, ignite fuel and close ashpit door
when fuel is well alight with spinwheel on ashpit
door at required setting.
(6. Allow the cooker to heat up gradually at first time
lighting.
NOTE: The water capacity of the boiler is 7 litres.
The firebricks fitted to Rayburn Cookers are of first
quality manufacture, and providing the cooker has been
installed and used correctly will have a reasonable life.
They are, however, expendable items and in time will
require renewal.
The renewal of firebricks is not a major operation and
can be carried out by the average person.
Replacement bricks either in sets or singly can be
obtained from your Rayburn distributor.
7
TESTING AND COMMISSIONING
FIREBRICK REPLACEMENT
LEAVE INSTRUCTIONS FOR FUTURE USE