Redring CD-RW901SL Water Dispenser User Manual


 
6
Fixing the unit on the wall
Use the wall mounting bracket supplied and the two lower fixing holes.
An extra top fixing point is available by temporarily removing the condenser assembly.
Connecting the water supply and vent pipes
When the unit is fixed to the wall, make the final water supply and steam vent connections
and secure the pipe work.
Switch the water supply back on.
Connecting the mains cable
Ensure the mains supply is isolated.
Connect the mains cable from the SB
2
to the 13 Amp fused isolating switch. Ensure
the cable clamps are firmly secured and the cable ends are tightened into the terminal block.
Note: The supply cable must be a minimum of 1.0mm
2
three core multi strand PVC insulated
mains cable. The terminal block will not accept cable diameters above 1.5mm
2
. Check that the
mains supply matches the electrical rating on the product. The rating plate is located on the
bottom edge of the unit.
IMPORTANT: Connect the supply cable, complying with BS6500, to this appliance in accordance
with the following code:
GREEN AND YELLOW (EARTH) connect to terminal marked " ".
BLUE (NEUTRAL) connect to terminal marked "N"
BROWN (LIVE) connect to terminal marked "L"
WARNING: THIS APPLIANCE, AND ALL METAL PIPE WORK CONNECTED TO IT, MUST BE
EARTHED.
Replacing the front cover
Support the cover and re-attach the flying lead to the unit (See Fig. 5a and Fig. 5b).
Replace the front cover and secure using the top and bottom fixing screws.
Carefully replace the knob, ensuring correct alignment of the D shaft.
Reconnect the mains supply.
Schematic
Wiring
Diagram