Adds auto field to preserve existing configurations.
Improve PC to Sun mouse movement
The sample rate has been increased from 20 samples/sec. to 40 samples/sec which
makes smoother mouse movement. This also corrects incorrect operation of devices
connected to the mouse port such as extenders or other KVM switches which did not
respond to the mouse sample rate. This includes older firmware version of the
Crystal View and other Rose KVM switches such as the Vista series.
Add mode commands for USB
Adds mode commands 11 and 12 to allow setting the USB-PC and USB-Sun settings
on units without OSD.
Add support for Compaq insight remote board
A problem occurs, if you have the keyboard and mouse ports on the board installed
in the Compaq server to the Rose switch.
When you use the local mode to access the
server the mouse works fine. When you log into the server through a browser, the
mouse does not work at all. This firmware upgrade fixes the remote mouse not
working.
Fix OSD label display
Fix label display routines so that a label time of zero causes no label to be displayed
unless Left Control-d is typed, in which case it is displayed for 5 seconds.
Program version UP16G 08/24/2000
Improve mouse performance
Improve compatibility with mouse on various platforms. Mouse would go out of sync
on various platforms such as HP LDpro and LXpro. This has been resolved.
Fix mouse on cascaded units
Fixed problem with out of sync mouse when expansion unit > 4.
Fix Sun extra enter key
Fixed extra enter key being sent from key repeat when closing CPU select window on
Sun CPU's.
Fixed out of sync mouse on Crystal View
Fixed problem with mouse going out of sync when using CrystalView attached to
user port. This is only when changing computers from the on-screen display menu.
Add sync control
Add support for forcing sync type on user port. When OSD firmware version 4.4 or
greater is installed extra fields appear on the configure overlay - resolution setting.
These fields allow you to force the output sync format to be either HV or composite
regardless of the input sync. This allows you to use a composite sync only monitor
with PCs or a PC monitor with computers producing composite sync such as Suns or
Unix workstations.
Program version UP16 8/30/1999
Fix upper boards not recognized
Fix problem with upper boards sometimes not being recognized at power up.
Randomly, certain units would not recognize the upper boards and you could not
switch to these ports.