Royal Consumer Information Products Super Hot Toater Toaster User Manual


 
72/,*+77+($33/,$1&(
1.
Pull the adjustment lever out, this will reduce the warming up period.
2.
Press and turn the gas control until the indicator mark is aligned with the IGN mark and keep the control fully
depressed.
3.
After a sufficient period has elapsed to allow the system to be purged of air, press and release the igniter
button until a pilot flame has been established, (check that the pilot has lit on both the ports. Keep the
control depressed for a further 20 seconds.
4.
Release the gas control and check that the pilot remains lit.
5.
Depress the gas control slightly and turn fully anti-clockwise until the indicator mark is aligned with the small
flame symbol. The burner will cross light from the pilot.
6.
Depress the gas control slightly and turn clockwise until the indictor mark is aligned with the large flame
symbol. The burner will now be at maximum rate.
7.
Turn the gas control to the OFF position, wait for 3 minutes, fully depress the gas control, turn to IGN position
and release the control. Attempt to ignite the pilot with an already lighted match or taper. If the pilot ignites the
FSD is faulty.
8.
Re-light the appliance. With the adjustment lever pulled forward and the control set to the maximum rate
(large flame) position, place the Fire front & fret in position and leave to heat up for 5 minutes, and check for
satisfactory clearance of products by inserting a lighted smoke match into the opening in the position shown in
Fig 10, i.e. 100mm below the top, and 40mm inside of the front face of the opening. All the smoke must be
drawn into the flue. If spillage occurs, allow a further 10 minutes. Should spillage still occur examine the
chimney for the fault and rectify the cause. The test should be repeated if an extractor fan is situated in the
room, or in any connecting room, with all the doors in that room opened.
9.
Remove the Fret and push the flame adjustment lever inwards, replace the Fret and check that the flame picture
changes to a longer softer flame.
Demonstrate the lighting and extinguishing procedures to the user.
$'9,6(7+$7
:
The curing effect of heating the coals will cause an initial odour, which although not harmful, may require
additional ventilation until the odour has disappeared.
The appliance must be serviced annually by a competent person; i.e. a CORGI registered installer in
accordance with these instructions and that the appliance is checked for spillage in accordance with the method
detailed in these instructions.
The appliance is fitted with an Oxy-pilot to prevent the continued operation in the event of spillage occurring. If
the fire shuts OFF repeatedly the appliance must be turned off and not used until an expert is consulted.
Advise the customer that they should read their Users Instructions before operating the fire and always follow
the advice in the section headed `Removal of Debris or Soot Deposits'
Complete the section in the enclosed registration leaflet. Advise that any component or part of this appliance is
guaranteed against defective workmanship or faulty materials for a period of twelve months from the date of
purchase.
Any such part will be replaced free of charge on receipt of the purchasers address at the cost of postage only,
provided that:
It is accompanied by the registration section cut out of the booklet together with the original purchase receipt,
which will be returned with the replacement part.
a)
A competent person has carried out installation repairs or adjustments, such as the supplier's representative
or a CORGI registered installer.
Page 7