Samsung RF267AEWP Refrigerator User Manual


 
62
TROUBLESHOOTING
5) If F Sensor has trouble
Bad contact of connector/ insert correctly
Are MAIN PCB
Connector CN30 to CN76 inserted
correctly?
Is F Sensor
unit normal?
Is the voltage between
MAIN PCB Connector CN30#3 (Red) and REG1,
HEAT SINK normal?
Is the input voltage of
IC01 MICOM #81 normal?
Start
NO
YES
YES
YES
YES
Replace temperature sensor
NO
Check the contact of PCB & Wire
Terminal correctly.
NO(0.6V > Measurement < 4.6V)
Check the iced-solder, solder bridging,
disturbed solder. Replace the PCB
NO
No trouble with PCB and temperature sensor
Recheck the bad contact of the connection
** Measuring point of resistance value according to
Sensor **
F : CN30#3 CN76#1 measuring resistance value
** 0: Short trouble / : Open trouble
Sensor MICOM/Connector number
Voltage measured between 4.6V ~ 0.6V.
Measuring voltage of IC01 MICOM #81,
CN30-"3"(Yellow) and REG1, HEAT SINK from PCB
typical Ground part are similar.
Check the measure on the SENSOR MARKING
#1(R309) due to the SMD MICOM
Checking method of F Sensor resistance
CN30#3(Red) CN76#1(Gray)
-
Compare the temperature table after the measure
DATA1.
Temperature table
ERROR Code
Refer to circuit diagram in the manual
F
Connector Cn30#3(Red) to
REG1 HEAT-SINK PCB common Ground
Checking method of F Sensor voltage
- Measure the voltage of Sensor Check Point #1
(IC01 MICOM #81) or CN30#3(Red) REG1, HEAT SINK.
- Compare the temperature table after the measure. Measuring
voltage of CN30#3(Red) REG1, HEAT SINK are below.
typical PCB Ground
REG1 HEAT-SINK
2¢(-17¡) is recommended 38¢(3¡) is recommended
Start
YES
YES
YES
    