Samsung RF267AEWP Refrigerator User Manual


 
78
TROUBLESHOOTING
4-2-11. When refrigerator ROOM Lamp does not light up
1. When you replace the lamp of freezer, please power OFF to avoid an electric shock.
2. Please keep in mind you could get burnt by the excessive heating of an incandescent light bulb.
3. Bimetal is installed in the refrigerator LAMP. Check that if LAMP may be turned OFF by bimetal.
We only explaine about Fresh Food compartment in this page.
Because it is possible to repair the other room lamps with the same method.
1) AC Lamp
(Option)
Start
Is the inside lamp
filament cut?
Is Lamp OFF by
bimetal operating?
Is the connection
point of R-door switch
normal?
Is the control relay
of the inside lamp in PCB
normal?(RY75)
Repair the inside lamp
Fresh food compartment
AC Lamp is applied only.
Repair door switch
Replace PCB and
Replace Relay
Check the connection of RDoor
switch and repair the inside lamp
socket
Reference
* The interior lamp relay operates lighting/lightout
according to door open / close.
* If interior lamp does not light, check the noise of relay
operation.
* Noise of relay operation sounds every Door Open /
Close.
* F-LAMP Relay -- RY74
* R-LAMP Relay -- RY75
Reference
If the door is opened, the contact of door switch will be opened and MICOM will get applied 5V to finally sense Open.
If 5V has been sensed over tree minutes afterwards, Door-Open alarm will sound Ding-Dongfor 10 seconds in a one minutes cycle.
For that reason, if the door switch has failure, the refrigerator can make a Ding-Dongsound with oneminute cycle. Please note the
step for its service.
Wait for returning time
of bimetal
When measure lamp resistance to the Wire
Resistance can be changed by Lamp input voltage.
(Actual measurement is below, it can be changed by
performance)
Checking method of Door Switch voltage
- Measuring voltage of CN30#2(Purple), CN30#1(black) and REG1, HEAT SINK
from PCB typical Ground part
See the R DOOR Switch at the following picture.
Wire color changed from
the following picture
Fresh food
compartment lamp
CN70#9(Red)
CN71#1 (Blue) ;
10Ohm5%
Lamp ; 60W + 60W
Freezer
compartment lamp
CN70#9(Red)
CN71#3 (Gray) ;
15Ohm5%
Lamp ; 60W
Typical PCB Ground REG1 Heater Sink
CLOSE
OPEN
Door & MICOM State
Door
F
MICOM
(#83)
Close
Open
5V(High)
0V(Low)
0V(Low)
5V(High)
R(Option)
R MICOM(#82)
Right and Left
    