CME1356R and CME1656R
March 2003
Page 45
Before Calling for Service
Check the following:
1. Has the water supply to the ice machine or building been shut off? If yes, the
ice machine will automatically restart within 25 minutes after water begins to
flow to it.
2. Has power been shut off to the ice machine? If yes, the ice machine will
automatically restart when power is restored.
3. Has someone disconnected power to a central condenser (probably on the
roof - may be connected to a walk-in cooler). If yes, the ice machine may need
to be manually reset.
4. Does the bin control have ice on it? If so, remove the ice and the machine
should start in a few minutes.
To Manually Reset the machine.
1. Remove the left front panel.
2. Locate the AutoIQ Controller. If a red
diagnostic light is glowing, note which one
and its blink rate. Then push and release the
off button.
3. Push and release the Freeze button.
4. The machine should begin to operate. If
there is a lack of water it will soon shut off
again.
5. Return the front panel to its normal
position.
If the machine shuts down again, call for
service.
To Shut the Machine Off:
1. Remove the left front panel.
2. Locate the AutoIQ Controller.
1
2
3
4
5
6
7
89
BIN FULL
FREEZE
HARVEST
CLEAN
OFF
WATER
REFRIGERATION
PUSH BUTTON
CONTROL SWITCHES
INDICATOR LIGHTS:
DIAGNOSTIC LIGHTS:
3. Push and hold the Off
button for 3 seconds or until