NME454, 654 & FME504, 804
January 2007
Page 16
OPERATION: Performance
Typical Low Side Pressure
·
Air Cooled: 34 - 38 PSIG
·
Water Cooled: 32 PSIG
Typical Discharge Pressure
·
Air Cooled: 220 - 300 PSIG
·
Water Cooled: 245 PSIG
Typical Compressor Amp Draw
·
8-9
Typical Auger Drive Motor Amp Draw (115
volt)
·
3.1 to 3.5 - Emerson
·
4to4.5-GE
Superheat
·
5 - 7 degrees
High Pressure Cut Out - automatic reset
·
450 PSIG
Low Pressure Cut Out - automatic reset
· 15 PSIG
Fan Motor Watts
·
35 Watt