8 PREPARATION OF THE OVEN
1. Rest the oven on its side as shown in Figure 7. Place portion (C)
of the carton underneath to protect the outercase from being
damaged.
2. Remove the two screws which secure the mounting plate to the
r
ear side of the oven. Remove the mounting plate. The two
screws can be discarded.
NOTE: If the unit you purchased does not have the mounting plate
attached to the rear side of the oven, please disregard this section
and continue to Section 9.
9 VENTILATION SYSTEM
This Microwave Oven/Hood System is designed for adaptation to
three types of hood ventilation systems. Select the type required for
your installation.
A. RECIRCULATING — Non-Vented, Ductless Operation
The unit is shipped assembled for recirculating.
NOTE:
1. The Exhaust Damper Assembly is not required for recir-
culating operation.
2. The Charcoal Filter should be replaced every 6 to 12
months, depending on use.
3. The Charcoal Filter RK-220 is also sold as an accesso-
ry. See Operation Manual for ordering information.
B. HORIZONTAL EXHAUST — Outside Ventilation
1. Remove and save the 4 screws from Fan Cover
Bracket. Remove Fan Cover Bracket by sliding it in the
opposite direction of the arrow on the Fan Cover
Bracket, as shown in Figure 8.
2. Lift Hood Fan Unit carefully and slip wires out of cavity.
See Figure 9.
CAUTION: Do not pull or stretch hood fan wiring.
3. Rotate the Hood Fan Unit 180˚ so that the fan blade
openings are facing the back of the oven. Note, you will
need to lift the wire over the hood fan unit so the wire will
clear. See Figure 10 (A). Replace Hood Fan Unit into the
oven. Be careful not to pinch the wire and the Hood Fan
Unit. See Figure 10 (B).
4. Put the wire back into the cavity
.
5.
Replace the fan cover bracket. Make sure the fan blades
are visible through the rear openings in oven before pro
-
ceeding. Attach the fan cover bracket to the unit with the
4 screws removed in step 1 above. See Figure 11. The
hood fan is now rotated for horizontal exhaust operation.
6. Attach the Exhaust Damper Assembly to the back of the
mounting plate by sliding it into the slits in the same
direction as the arrow
. See Figure 12. Using tapping
screw 4 x 12 mm from the INST
ALLA
TION HARD
-
W
ARE, tighten into place.
4
Figure 7
Mounting plate
Grease filter openings
Fan Cover Bracket
Figure 8
Figure 9
Figure 10
(A) Rotate 180˚
(B)