Sharp TINSKB147MRR1 Microwave Oven User Manual


 
E 3
Figures 3, 4 and 5 contain many Microwave Drawer measurements
for reference when planning the drawer’s location.
This Microwave Drawer can be installed below any electric or
gas wall oven.
* Can also be installed using an electrical outlet in an adjacent
cabinet within the area where the provided electrical cord can
reach. Power cord access hole in cabinet should be a minimum
1
1
/2" diameter hole and deburred of all sharp edges.
IMPORTANT
Always allow sufcient power cord length to the
electrical outlet to prevent tension.
Always check electrical codes for requirements.
30" mICRoWAvE dRAWER mEASUREmENtS


To reduce the risk of tipping of the drawer, the Anti-Tip block must
beproperlyinstalledlocated1413/16-inchesabovetheooron
which the Microwave Drawer will sit. The 6-inch Anti-Tip block
must be provided by the installer. See Figures 1 and 6 (for 24") or
Figures 3, 4 and 6 (for 30"). The Anti-Tip block prevents serious
injury that might result from spilled hot liquids.
If the Microwave Drawer is ever moved to a different location, the
ANtI-tIP BLoCk
Anti-Tip block must also be moved
and installed. When installed to
the wall, make sure that the screws
completely penetrate the dry wall
and are secured in wood or metal
so that the block is totally stable.
When fastening, be sure that the
screws do not penetrate electrical
wiring or plumbing.

4"
(101.6 mm)
5" (127 mm)
6"
(152.4 mm)
3 1/2"
(89 mm)
Suggested electrical
outlet location*
Anti-Tip block
A
B
C
D
E
F
G
H
I
I
J
K
L
M
N
O
P
Q
A
B
C
D
E
F
G
H
I
J
K
L
M
M
N
O
P
Q
R
S


A
B
C
J
D
E
F
G
H
I

A. 84" (2133.6 mm) wall
cabinet
B. Optional wall oven
cutout illustrated in
sketch
C. Suggested electrical
outlet location*
D. 6" (152.40 mm)
E. Anti-Tip block
F. 3-1/2" (88.90 mm)
G. 5" (127 mm)
H. 4" (101.60 mm)
I. 2" (50.8 mm) minimum
J. 28-7/16" (722.3 mm)
opening
K. Allow 3/16" (4.76 mm)
overlap
L. 14-13/16" (376.24 mm)
to bottom of Anti-Tip
block
M. Allow 3/4" (19.05 mm)
overlap
N. 23-1/2" (596.9 mm)
minimum depth
O. 14-13/16" (376.24 mm)
opening
P. Allow 7/16" (11.11 mm)
overlap
A. 6" (152.40 mm)
B. Suggested electrical
outlet location*
C. Anti-Tip block
D. 5" (127 mm)
E. 3-1/2" (88.90 mm)
F. 4" (101.60 mm)
G. 28-7/16" (722.31 mm)
opening
H. 14-13/16" (376.24 mm)
to bottom of Anti-Tip
block
I. Allow 3/4" (19.05 mm)
overlap
J. 23-1/2" (596.9 mm)
minimum depth
Q. Floor must support 100 lb (45.4 kg)
R.19"(482.6mm)totopofoor(recommended)
S. 30" (762 mm) cabinet minimum
K. Allow 3/16" (4.76 mm) overlap
L. 36" (914.4 mm) countertop height
M. Allow 7/16" (11.09 mm) overlap
N. Floor must support 100 lb (45.4 kg)
O.19"(482.6mm)totopofoor(recommended)
P. 30" (762 mm) cabinet minimum
Q. 14-13/16" (376.24 mm) opening
A. 21-5/8"
(549.28 mm)
B. 4-11/16"
(119.06 mm)
C. 1-3/4"
(44.45 mm)
D. 21-7/8"
(555.63 mm)
E. 30" (762 mm)
F. 15" (381 mm)
G. 14-19/32" (370.68 mm)
H. 1-11/16" (42.86 mm) door thickness
I. 15" (381 mm) auto drawer opening
J. 4" (101.6 mm)