Fault: Cause/Remedy
The appliance does not
operate after connection to the
mains:
Check if there is power in the socket and if the
appliance is switched on.
Cooling system operates
continuously without
intermittent stoppages:
Ambient temperature too high.
Frequent opening of the door, (open too long).
Door not closed properly (particle between door
gasket, sagged door, check gasket sealing, etc...).
Excessive quantity of fresh food inserted at once.
• Refrigerator sensor (A) is crammed with fresh food.
Free the sensor and allow air to circulate around it.
Check air circulation for suf cient cooling of the
compressor, and clean the condenser.
Excessive ice formation at
the rear interior wall of the
refrigerator:
Frequent opening of the door, door open too long.
Placing hot food in the refrigerator.
Food is touching the rear interior panel.
Bad door sealing; clean or replace the gasket if
dirty or damaged.
Water dripping from the
appliance:
Drain outlet is clogged, drain water drips past the
collection groove.
Clean the clogged outlet using plastic straw.
Please thaw out larger ice deposits manually (see
chapter Defrosting).