Smeg A2-2 Cooktop User Manual


 
Instructions for the installer
3. ADAPTATION TO DIFFERENT TYPES OF GAS
Before performing any cleaning or maintenance work, detach the
appliance from the electrical socket.
The cooker hob is set for natural gas G20 (2H) at a pressure of 20 mbar.
In the case of functioning with other types of gas the burner nozzles must
be changed and the minimum flame adjusted on the gas taps. To change
the nozzles, proceed as described below.
3.1 Replacement of nozzles on the hob
This operation requires no primary air regulation.
1. Extract the grids and remove all the caps and flame-spreader
crowns;
2. unscrew the burner nozzles with a 7 mm socket wrench;
3. replace the nozzles according to the type of gas to be used and the
description in paragraph “3.2 Burner and nozzle characteristics
table”.
Replace the burners in the correct position.
42